Axcelis
Provisional entry — research in progress
This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.
The Axcelis 9355 UPS is a 15 kVA / 13.5 kW uninterruptible power supply. The 9355 UPS is a three-phase, double-conversion online UPS. The 9355 UPS is a tower-configuration unit with internal batteries, an integrated power distribution module, and a maintenance bypass switch.[1][2]

The Eaton 9355 UPS is a three-phase double-conversion online uninterruptible power supply. The unit is also known as the Powerware 9355. The 9355 UPS provides backup power protection for critical loads in data centers and other facilities. The system is designed in a tower form factor and is available in power ratings from 10 kVA to 30 kVA. The 9355 UPS includes internal batteries, an integrated power distribution module, and a maintenance bypass switch.[3][2][4][1][5]
The 9355 UPS uses double-conversion topology, meaning the incoming AC power is rectified to DC and then inverted back to clean AC power, isolating connected equipment from all common electrical disturbances. The unit continuously monitors incoming power and corrects surges, sags, spikes, and other irregularities. Internal batteries provide emergency power during brownouts and blackouts. The UPS employs Advanced Battery Management (ABM) technology with a three-stage charging technique to extend battery life. Temperature-compensated charging adjusts the charge rate based on battery temperature. The system can parallel up to four 9355 UPS units using Eaton's Powerware Hot Sync technology for additional capacity or redundancy. Hot Sync enables wireless paralleling even if communications fail.[2][1]
The 9355 UPS includes a graphical LCD with a blue backlight that displays load status, events, measurements, and settings. The unit has four LEDs for notice and alarm, audible alarms, and communication ports including RS-232, relay contact, REPO, and environmental inputs. The UPS self-diagnoses by constantly monitoring voltage, temperature, and internal components. If a problem is detected, the unit automatically transfers the power path to a bypass source with no interruption.[1]
The 9355 UPS is installed between the facility's utility power and sensitive electronic equipment to ensure clean, uninterrupted power. In a data center or server room, the UPS protects servers, networking devices, and storage systems from power anomalies. The unit can be placed at the end of a row of racks (end-of-row configuration) and supplies power to downstream power distribution units or directly to equipment. The internal batteries and integrated power distribution module reduce the need for external battery cabinets and additional power strips, simplifying installation.[2][1]
The 9355 UPS is intended for corporate data centers, telecom and networking environments, healthcare facilities, banking systems, industrial settings, and retail operations. The system provides backup power for IT infrastructure, electrical engineering equipment, and other critical systems. UL 924 emergency lighting models are also available.[2][4][1]
Documented failure modes, common issues, and field considerations.
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| 9355 10 kVA with 32-Battery (2-high) | — | — | 10 kVA / 9 kW; 208/208 or 220/220 input/output voltage | eatonguard.com[2] |
| 9355 10 kVA with 64-Battery (3-high) | — | — | 10 kVA / 9 kW; 208/208 or 220/220 input/output voltage; 3-high battery configuration | eatonguard.com[2] |
| 9355 15 kVA with 32-Battery (2-high) | — | — | 15 kVA / 13.5 kW; 208/208 or 220/220 input/output voltage | eatonguard.com[2] |
| 9355 15 kVA with 64-Battery (3-high) | — | — | 15 kVA / 13.5 kW; 208/208 or 220/220 input/output voltage; 3-high battery configuration | eatonguard.com[2] |
| 9355 20 kVA with Internal Batteries | — | — | 20 kVA (18 kVA) model class; 208/208 or 220/220 input/output voltage | eatonguard.com[2] |
| 9355 30 kVA with Internal Batteries | — | — | 30 kVA (27 kVA) model class; 208/208 or 220/220 input/output voltage | eatonguard.com[2] |
| 9355 10 kVA with Input Isolation Transformer (3-high) | — | — | 10 kVA / 9 kW; 480/208 or 600/208 input/output voltage | eatonguard.com[2] |
| 9355 15 kVA with Input Isolation Transformer (3-high) | — | — | 15 kVA / 13.5 kW; 480/208 or 600/208 input/output voltage | eatonguard.com[2] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The Eaton 9355 UPS is available in power ratings from 10 kVA to 30 kVA.[1][5]
The 9355 UPS supports input voltages of 208/220/400/480/600 VAC three-phase, depending on the model and configuration.[1][5]
Yes, up to four 9355 UPS units can be paralleled for additional capacity or redundancy using Eaton's Powerware Hot Sync technology.[2][1]
The 9355 UPS uses sealed, lead-acid, maintenance-free batteries (9 Ah).[1]
The following facts about the 9355 UPS are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 9355 UPS are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the 9355 UPS are not on record.
Answerable by: an engineer who operated it or OEM installation records
The process node or technology generation of the 9355 UPS is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the 9355 UPS are on record.
Answerable by: an OEM parts catalog or a service engineer
No publicly hosted manuals, SOPs, or datasheets for the 9355 UPS are on record.
Answerable by: university cleanroom staff or an OEM application specialist
Last updated Sep 29, 2026.
The KLA .204 PSL Wafer is an 8-inch NIST-traceable reference wafer compatible with Surfscan 6xy0 and Sp1 particle counters.
KLA .496 PSL Wafer is an 8-inch NIST traceable wafer stated to be capable on Surfscan 6xy0 and SP1.
The KLA .498 PSL Wafer is a NIST traceable reference wafer.