Waferpedia

Comparison ledger

9355 UPSversus1.112 PSL Wafer

Axcelis 9355 UPS, KLA 1.112 PSL Wafer, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
9355 UPSAxcelis
OEMAxcelisKLA
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyAxcelis 9355 UPSKLA 1.112 PSL Wafer
Cited variants
  • 9355 10 kVA with 32-Battery (2-high)[1]
  • 9355 10 kVA with 64-Battery (3-high)[1]
  • 9355 15 kVA with 32-Battery (2-high)[1]
  • 9355 15 kVA with 64-Battery (3-high)[1]
  • 9355 20 kVA with Internal Batteries[1]
  • 9355 30 kVA with Internal Batteries[1]
  • 9355 10 kVA with Input Isolation Transformer (3-high)[1]
  • 9355 15 kVA with Input Isolation Transformer (3-high)[1]
—
Specifications
Power15kVA/ 13.5kW[2]—
ConfigurationDefective batteries[2]NIST Traceable[5]
MakeAxcelis[2]—
Model9355[2]—
Product typeAC Back-up Power (UPS)[3]—
Axcelis 9355 UPS rating15 kVA / 13.5 kW[2]—
Power rating10-30 kVA[1]—
TopologyDouble conversion[4]—
Voltage208/220/400/480/600 Vac three phase[1]—
Frequency50/60 Hz[1]—
Output power factor0.9[1]—
Input power factor>0.99 typical (10-15 kVA); 0.99 typical (20-30 kVA)[4]—
Input current distortion5% THD[4]—
Internal batteriesStandard on all configurations[1]—
Integrated power distribution moduleOn-board, plug-and-play power distribution module[1]—
Maintenance bypass switchIntegrated maintenance bypass switch[1]—
ParallelingUp to four 9355 UPS units for capacity or redundancy using Powerware Hot Sync technology[1]—
Scalability10 kVA and 20 kVA configurations can be upgraded to 15 kVA and 30 kVA, respectively, without additional hardware[1]—
Battery type9 Ah, sealed, lead-acid, maintenance-free[4]—
Battery managementMicroprocessor-controlled ABM technology with three-stage charging[1]—
Battery replacementField-replaceable batteries[1]—
DisplayFour-button graphical LCD[1]—
Communication ports(1) RS-232, (1) relay contact, (1) REPO, (2) environmental input[4]—
Operating temperature50-104°F (10-40°C); 45°C with 7.5% derating[4]—
Overload capability150% for 5 s / 125% for 1 min (online); 110% for 10 min[4]—
Safety certificationsUL1778 5th Edition, CSA C22.2 No. 107.3-14, NOM-NYCE[4]—
Emergency lighting modelsUL924 Emergency Lighting models available[3]—
OEMAxcelis[2]—
PhaseThree-phase[1]—
Parallel capabilityUp to four units can be paralleled[1]—
Wafer Size—8 inch[5]
NIST Traceable—True[5]
Compatible Tools—Surfscan 6xy0 and Sp1[6]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →
Sources (6)Every fact above is drawn from these public sources
  1. [1]eatonguard.comeatonguard.com
  2. [2]inventory listing
  3. [3]hmcragg.comhmcragg.com
  4. [4]ajpowersupply.comajpowersupply.com
  5. [5]inventory listing
  6. [6]waferpedia.comwaferpedia.com