YES
The CV108 is a single-wafer, downstream plasma stripper/descummer. The CV108 removes photoresist or polyimide coatings from 150 or 200mm wafers. The CV108 uses microwave energy to ionize oxygen gas.[1][2]

Wafer size
200mm
Power
up to 2 kW per process chamber[1]
Vacuum
four-inch OD house exhaust[1]
Gas delivery
photoresist, polyimide and B.C.B. removal[1]
A downstream plasma stripper uses microwave energy to ionize oxygen gas and create an oxygen plasma.[1][2]
The oxygen plasma reacts with organic coatings and converts them to carbon dioxide and water vapor that are removed by vacuum exhaust.[1][2]
The downstream chamber design is intended to prevent ion acceleration and electron damage at the wafer surface.[1][2]
The CV108 uses two mass flow controllers, automated microwave tuning, variable microwave power, variable process pressure, and wafer-contact temperature control by thermocouple.[1][2]
The CV108 is used for photoresist, polyimide, and B.C.B. removal.[1][2][3]
The CV108 is used for removing photoresist coatings from wafers.[1][2]
The CV108 is used for removing polyimide coatings from wafers.[1][2]
The CV108 is used for removing B.C.B. coatings from wafers.[1][2][3]
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The following facts about the CV108 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the CV108 are on record.
Answerable by: OEM historical records or a trade-press announcement
No publicly documented variants, configuration options, or revision breakpoints of the CV108 are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the CV108 are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the CV108 are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the CV108 is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No research found yet — worked with this tool? Share what you know.