Waferpedia

YES

253B-2-50-2

Lab & Support EquipmentYES 253B-2-50-2 family
Research Quality: 40% complete

The MKS Type 253B Exhaust Throttle Valve is a butterfly valve. The MKS Type 253B Exhaust Throttle Valve is designed to regulate gas removal from a vacuum chamber. The MKS Type 253B Exhaust Throttle Valve uses a 15-pin Type D connector to connect to a controller.[1]

YES253B-2-50-2
No photo available yet

What it is

The MKS Type 253B is an exhaust throttle valve.[1]

What can it run?

Process applications and technology nodes documented for this tool.

  • Vacuum chamber gas flow control
  • Exhaust throttling
  • Use with high vacuum pumps including Roots blower, diffusion, turbo, and cryo pumps

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • The manual warns that operating with high vacuum diffusion pumps requires the pressure above the oil vapor jet not to exceed 0.5 milliTorr.
  • The manual states that routine cleaning may be necessary due to buildup of process contaminants.

What do the numbers mean?

Power & electrical1

Power input
±15 VDC, 1 Amp (30 Watts) nominal, user-supplied[1]
Accurate?

Vacuum & pumping3

Product name
MKS Type 253B Exhaust Throttle Valve[1]
Accurate?
Function
regulate gas removal from a vacuum chamber[1]
Accurate?
Maximum differential pressure across valve
1 atm (15 psig) max[1]
Accurate?

Optics & imaging1

Resolution
Standard: 1/10,000; Fast Motor Option: 1/2800[1]
Accurate?

Control & software1

Controller compatibility
Type 651, 652, 152G, or 252 (revision D or later) controllers[1]
Accurate?

Configuration & options7

Valve type
butterfly valve[1]
Accurate?
Connector
15-pin Type D connector[1]
Accurate?
Flange types
ASA, KF Style ISO, NW Style ISO, CF, JIS[1]
Accurate?
Heated valve body operating temperature
80° to 90° C (176° to 194° F) for 20° to 40° C (68° to 104° F) ambient[1]
Accurate?
Speed (open to close)
Standard: 7.5 sec; Optional: < 2 sec[1]
Accurate?
Valve body operating temperature
0° to 90° C (32° to 194° F) max[1]
Accurate?
Valve motor ambient operating temperature
0° to 70° C (32° to 158° F) max[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
253B-2-50-2——KF Style ISO valve with KF-50 mounting flange; 2.000 in (50.8 mm) inside diameter; 3.25 in (82.6 mm) outside diameter unheated and 3.50 in (88.9 mm) with heater option; controllable conductance 0.70 to 300 l/sec; thickness 2.00 in (50.8 mm); overall height 9.14 in (232.2 mm) unheated and 9.31 in (236.5 mm) with heater option.nanofab.utah.edu[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Product nameMKS Type 253B Exhaust Throttle Valve[1]
  • Functionregulate gas removal from a vacuum chamber[1]
  • Maximum differential pressure across valve1 atm (15 psig) max[1]
  • Power input±15 VDC, 1 Amp (30 Watts) nominal, user-supplied[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the Type 253B?

The Type 253B is an exhaust throttle valve.[1]

Not publicly documented

The following facts about the 253B-2-50-2 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 253B-2-50-2 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 253B-2-50-2 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the 253B-2-50-2 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 253B-2-50-2 are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the 253B-2-50-2 are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]nanofab.utah.edu — nanofab.utah.edunanofab.utah.edu
Was this page accurate?

Last updated Oct 9, 2026.

Compare with similar tools