Waferpedia

Edwards

IXL 1000 Dry

Edwards IXL 1000 Dry family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

EdwardsIXL 1000 Dry
No photo available yet

Power

1 kW[2]

Vacuum

0.001 mbar / 0.00075 Torr / 0.1 Pa[2]

How it works

The iXL1000 uses precision oil lubricated bearings throughout the pump and booster, and includes an integrated exhaust non-return valve to prevent contaminant suck-back from the house exhaust. A Green Mode reduces utility consumption during idle periods, lowering power draw to 0.05 kW when the pump is not actively evacuating a chamber.[2]

What do the numbers mean?

Power & electrical3

Power at ultimate
1 kW[2]
Accurate?
Supply voltage and frequency
200-460 V, 50/60 Hz[2]
Accurate?
Power in Green Mode
0.05 kW[2]
Accurate?

Vacuum & pumping1

Ultimate pressure (typical)
0.001 mbar / 0.00075 Torr / 0.1 Pa[2]
Accurate?

Dimensions & facilities3

Cooling water connection
3/8 in Quick Connect[2]
Accurate?
Weight
167 kg or 168 kg[2]
Accurate?
Footprint
0.195 m2[2]
Accurate?

Configuration & options10

Make
Edwards[1]
Accurate?
Model
IXL 1000[1]
Accurate?
Peak speed
930 m3/h / 547 cfm / 15500 l/min[2]
Accurate?
Inlet connection
ISO100[2]
Accurate?
Outlet connection
NW25[2]
Accurate?
Nitrogen connection
n/a or 1/4 in tube fitting[2]
Accurate?
Water flow
1.6 l/min[2]
Accurate?
Typical purge flow
0 slm or 0-40 slm (default 10)[2]
Accurate?
Noise
55 dB(A)[2]
Accurate?
Green Mode energy reduction
up to 96% during idle periods[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
iXL1000N——A variant with 1.1 kW power at ultimate, 0-40 slm typical purge flow (default 10), 168 kg weight, and 1/4 in tube fitting nitrogen connection.advancedvacuum.se[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Ultimate pressure (typical)0.001 mbar / 0.00075 Torr / 0.1 Pa[2]
  • Power at ultimate1 kW[2]
  • Supply voltage and frequency200-460 V, 50/60 Hz[2]
  • Power in Green Mode0.05 kW[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the peak pumping speed of the iXL1000?

The iXL1000 has a peak pumping speed of 930 m³/h, 547 cfm, or 15,500 l/min.[2]

What ultimate pressure can the iXL1000 achieve?

The iXL1000 achieves a typical ultimate pressure of 0.001 mbar (0.00075 Torr / 0.1 Pa). The iXL1000N variant achieves 0.002 mbar (0.0015 Torr / 0.2 Pa).[2]

How much power does the iXL1000 consume?

Average power consumption at ultimate pressure is 1 kW for the iXL1000 and 1.1 kW for the iXL1000N. In Green Mode, power consumption drops to 0.05 kW.[2]

What is the noise level of the iXL1000?

The iXL1000 operates at an average noise level of 55 dB(A) at ultimate pressure.[2]

What are the inlet and outlet connections of the iXL1000?

The iXL1000 has an ISO100 inlet connection and an NW25 outlet connection.[2]

What is the weight of the iXL1000?

The iXL1000 weighs 167 kg; the iXL1000N weighs 168 kg.[2]

Not publicly documented

The following facts about the IXL 1000 Dry are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the IXL 1000 Dry are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the IXL 1000 Dry are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the IXL 1000 Dry are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the IXL 1000 Dry is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the IXL 1000 Dry are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Equipment inventory listing
  2. [2]advancedvacuum.se — advancedvacuum.seadvancedvacuum.se
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools