Waferpedia

Bruker

Dimension 5000

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Bruker Dimension 5000 is an atomic force microscope (AFM) used for metrology and inspection. The Dimension 5000 supports sample sizes up to 300 mm diameter. The Dimension 5000 has a closed-loop positioning system with 1 µm resolution and 2 µm repeatability.[1][2][3]

Dimension 5000 — Inventory photo
Fig. 01Dimension 5000Inventory photo[1]

Performance

2 µm[2]

Optics

1 µm linear positioning resolution[2]

What it is

The Bruker Dimension 5000 is an atomic force microscope (AFM) manufactured by Bruker and is also branded with Veeco. The Dimension 5000 is a large-sample AFM that supports wafers up to 300mm in diameter. The system uses a closed-loop encoder-based positioning system with a linear positioning resolution of 1μm and a bidirectional repeatability of 2μm. The system supports multiple imaging modes including AFM, STM, conductive AFM, scanning capacitance, and spreading resistance imaging. Controller options include NanoScope IIIA, IV, or V. The optical system provides a motorized zoom and focus with a field of view of 150–675μm, and the sample inspection area is 200mm square.[1][2]

How it works

The Dimension 5000 employs a closed-loop encoder-based positioning system for high-accuracy scanning. The system is controlled by a NanoScope controller (IIIA, IV, or V) and includes a motorized zoom and focus optical system for sample viewing.[2]

What do the numbers mean?

Optics & imaging2

Resolution
1 µm linear positioning resolution[2]
Accurate?
Optical System
Motorized Zoom & Focus, 150–675 µm field of view[2]
Accurate?

Performance1

Bidirectional Repeatability
2 µm[2]
Accurate?

Control & software1

Controller
NanoScope IIIA, IV, or V[2]
Accurate?

Configuration & options4

Sample Size/Range
Up to 300 mm diameter[2]
Accurate?
Positioning System
Closed-loop (encoder-based)[2]
Accurate?
Imaging Modes
AFM, STM, Conductive AFM, Scanning Capacitance, and Spreading Resistance Imaging[2]
Accurate?
Sample Inspection Area
200 mm square[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the sample size capability of the Dimension 5000?

The Dimension 5000 can accommodate samples up to 300mm in diameter.[2]

What imaging modes are supported?

The system supports AFM, STM, conductive AFM, scanning capacitance, and spreading resistance imaging.[2]

What controller options are available?

Controller options include NanoScope IIIA, IV, or V.[2]

What is the positioning system specification?

The positioning system is closed-loop encoder-based with 1μm linear resolution and 2μm bidirectional repeatability.[2]

What is the optical system specification?

The optical system is a motorized zoom and focus with a field of view of 150–675μm.[2]

Who manufactured the Dimension 5000?

The Dimension 5000 was manufactured by Bruker, and the system is also branded with Veeco.[1][2]

Not publicly documented

The following facts about the Dimension 5000 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Dimension 5000 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Dimension 5000 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Dimension 5000 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Dimension 5000 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Dimension 5000 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]tarasemi.com — tarasemi.comtarasemi.com
  3. [3]Dimension 5000 — Bruker | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 1, 2026.

Compare with similar tools