Waferpedia

Comparison ledger

300 X Spinversus300

Brewer Science 300 X Spin, PVA TePla 300, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
300 X SpinBrewer Science
300PVA TePla
OEMBrewer SciencePVA TePla
CategoryResist ProcessingResist Processing
Wafer size—75 mm to 100 mm
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyBrewer Science 300 X SpinPVA TePla 300
Cited variants—
  • PVA TePla 300 AL (Autoload PC)[1]
  • PVA TEPLA 300 AL[1]
Specifications
P/N901445[2]—
ConfigurationHeavy Duty Drive[2]—
Drive TypeHeavy Duty Drive[2]—
Voltage208-240 V[2]—
Part Number901445[2]—
Plasma type—High frequency plasma[3]
Plasma frequency—2.45 GHz[3]
Plasma power—200 to 1000 W[3]
Gas—O2 (max. flow 500 ml/min)[3]
Chamber—Quartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[3]
Wafer capacity—Quartz holders for 25 wafers[3]
Wafer size range—75 mm to 100 mm[3]
Micro-electronic compatibility—Not micro-electronic compatible[3]
Category—Plasma etcher (resist strip / surface activation)[3]
Positive resist etch rate—350 nm/min[3]
Compatibility—Not micro-electronic compatible; gold allowed; Si, glass, Pyrex wafers[3]
Power Range—200 to 1000 W (or 0-1000 W)[3]
Process Gases—O2, Ar, N2, CF4[4]
Chamber Material—Quartz[3]
Chamber Dimensions (internal)—Diameter 245 mm x Depth 380 mm[3]
Wafer Holder Capacity—25 wafers[3]
Wafer Size—75 mm to 100 mm[3]
Wafer Size (alternate)—up to 6 inches[1]
Process Pressure—0.6 to 1.5 mbar[1]
Restricted Materials—Materials that deteriorate in oxygen (Ag, Cu, Cr, Fe, etc.) should not be processed; no Cr or other metals in chamber[3]
Microwave frequency—2.45 GHz[3]
Power range—200 to 1000 W[3]
Batch size—Up to 25 wafers[3]
Wafer diameter (standard carrier)—75 mm to 100 mm[3]
Process gases—O2, CF4, Ar, N2[4]
Maximum O2 flow—500 ml/min[3]
Chamber dimensions (internal diameter x depth)—245 mm x 380 mm[3]
Chamber internal dimensions—Dint. 245 mm x Prof. 380 mm[3]
Gas 1—O2 (max. flow 500 ml/min)[3]
Resist strip etch rate—350 nm/min depending on number of wafers[3]
Faraday cage—Available[3]
Process gas—O2 (max flow 500 ml/min)[3]
Chamber dimensions—Quartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[3]
Process type—High-frequency plasma[3]
Applications—Photoresist stripping; wafer surface cleaning; hydrophilic surface activation of plastics surfaces[3]
Carrier capacity—Quartz holders for 25 wafers[3]
Not micro-electronic compatible—This equipment is NOT micro-electronic compatible.[3]

Plan your fab

Building a Resist Processing process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]polifab.polimi.itpolifab.polimi.it
  2. [2]inventory listing
  3. [3]epfl.chepfl.ch
  4. [4]nist.govnist.gov