Waferpedia

Comparison ledger

-407B-1-S-CES293 RobotversusTMU 064 Turbomolecular

ABM -407B-1-S-CES293 Robot, Pfeiffer TMU 064 Turbomolecular, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMPfeiffer
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-1-S-CES293 RobotPfeiffer TMU 064
Cited variants—
  • TMH 064[1]
  • TMU 064 U SG DN 63 CF-F[1]
Specifications
ModelABM-407B-1-S-CES293[2]TMU 064[3]
DescriptionROBOT[2]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2]—
Configuration—With TCP015 Controller[3]
Equipment type—Turbomolecular pump[1]
Make—Pfeiffer[3]
Controller—TCP015 controller[3]
Pumping speed for N2—53 l/s[1]
Pumping speed for He—42 l/s[1]
Pumping speed for H2—31 l/s[1]
Nominal rotation speed—90,000 l/min[1]
Standby rotation speed—60,000 l/min[1]
Run-up time—2.5 min (up to 90% rated rotation speed)[1]
Noise level—< 50 dB(A)[1]
Final pressure, backing pump—≤ 5 mbar[1]
Inlet—DN 63 ISO-KF / DN 63 CF-F[1]
Outlet—DN 16 ISO-KF / G 1/4"[1]
Venting connection—G 1/8"[1]
Maximum permissible rotor temperature—90°C[1]
Permissible heat radiation power—4 W[1]
Maximum fore-vacuum pressure for N2—14 mbar[1]
Maximum fore-vacuum pressure for He—10 mbar[1]
Maximum fore-vacuum pressure for H2—6 mbar[1]
Maximum gas throughput for N2—1.1 mbar[1]
Maximum gas throughput for He—1.5 mbar[1]
Maximum gas throughput for H2—1 mbar[1]
Final pressure with diaphragm vacuum pump—< 1 x 10^-8 mbar[1]
Final pressure with rotary vane vacuum pump—< 2 x 10^-10 mbar[1]
Lubricant—TL 011[1]
Cooling type—standard convection[1]
Cooling water consumption—15 l/h with water at 15°C[1]
Cooling water temperature—5-25°C[1]
Permissible ambient temperature with air cooling—0-35°C[1]
Heating power consumption—40 W[1]
Weight—3.6 / 3.8 kg[1]
Permissible magnetic field—4 mT[1]
Sources (4)Every fact above is drawn from these public sources
  1. [1]ptbsales.comptbsales.com
  2. [2]dealer listingsemistarcorp.com
  3. [3]inventory listing
  4. [4]inventory listing