Waferpedia

Comparison ledger

ASL 3000versusETS 200 T

LTX-Credence ASL 3000, Teradyne ETS 200 T, side by side. Every value shown is drawn from the cited encyclopedia entries.

Documented as functional equivalents— Same function class: Test & Probe, Unknown[1]
Side-by-side comparison of selected equipment models
Attribute
ASL 3000LTX-Credence
ETS 200 TTeradyne
OEMLTX-CredenceTeradyne
CategoryTest & ProbeTest & Probe
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyLTX-Credence ASL 3000Teradyne ETS 200
Specifications
ConfigurationTester boards:[2]With Electroglas EG 4090 & 4090 u+ Prober (8")[1]
Vate5.3.0SP1[2]—
Instrumentation rackRS SMIQ 06 ATE, Gigatronics 8651A, Agilent 34401A, MVNA[3]—
Tester BoardsOVI (4), TMU, DVI2k (4), MUX LV, MDI (4), CLK4[2]—
Computer ProcessorPentium 4[2]—
RAM1 GB[2]—
Hard Drive80 GB HDD[2]—
Operating SystemWindows NT 4.0[2]—
Software VersionVate 5.3.0SP1[2]—
Vintage2007[3]—
Board Complement (Part Numbers)OVI (Octal VI Card) 671 3032 (4), TMU (Time Measurement) 671 5333, DVI 300 671 4678, DVI 2000 671 4676 (2), MUX (Relay Mux Card) 671 5351, MDI 671 4534, CLK 4 672 6135, BTB 4 (Baseband transition board) 671 5366, Brick (16 Ports) 650 4717[3]—
ProcessorPentium 4[2]—
HDD80 GB[2]—
SoftwareVate 5.3.0SP1[2]—
Tester boards includedOVI (4), TMU, DVI2k (4), MUX LV, MDI (4), CLK4[2]—
OVI (Octal VI Card) 671 30324 units[3]—
TMU (Time Measurement) 671 53331 unit[3]—
DVI 300 671 46781 unit[3]—
DVI 2000 671 46762 units[3]—
MUX (Relay Mux Card) 671 53511 unit[3]—
MDI 671 45341 unit[3]—
CLK 4 672 61351 unit[3]—
BTB 4 (Baseband transition board) 671 53661 unit[3]—
Brick (16 Ports) 650 47171 unit[3]—
Slot 1Octal VI Card: Assy 950033-04, Rev E[5]—
Slot 2Pulsed V/I V3: Assy 617-7096-00[5]—
Slot 3Octal VI Card: Assy 950033-02, Rev D[5]—
Slot 4Pulsed V/I V3: Assy 950062[5]—
Slot 6Time Measurement Unit: Assy 950012[5]—
Slot 8Dual OP-AMP Loop Card: Assy 960006-04[5]—
Slot 104 Quadrant V/I: Assy 671-4678-00[5]—
Slot 14Relay MUX Card: Assy 960013-06[5]—
Slot 15Octal VI Card: Assy 671-3032-36, Rev A[5]—
Slot 16Octal VI Card: Assy 950033-04, Rev E[5]—
Slot 17Octal VI Card: Assy 950033-04, Rev E[5]—
Slot 20Relay MUX Card: Assy 960013-06[5]—
Slot 244 Quadrant V/I: Assy 671-4678-15, Rev A[5]—
Slot 264 Quadrant V/I: Assy 671-4578-25, Rev A[5]—
Slot 27Assy 678-4548-03, Rev A[5]—
Empty Board Slots7, 9, 11, 12, 13, 18, 19, 21, 22, 23, 25[5]—
Computer configurationPentium 4 processor, 1GB ram, 80 GB HDD, Windows NT 4.0, Vate 5.3.0SP1[2]—
Electrical requirements208-240 VAC, 50 A, 50/60 Hz[5]—

Plan your fab

Building a Test & Probe process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]inventory listing
  3. [3]inventory listing
  4. [4]inventory listing
  5. [5]inventory listing