The Thermo Scientific Dionex UltiMate 3000 is a high-performance liquid chromatography (HPLC) system designed to support both conventional HPLC methods and ultra-high-performance liquid chromatography (UHPLC) applications.[1]
The UltiMate 3000 standard systems support operating pressures up to 620 bar (approximately 9,000 psi) and flow rates up to 10 milliliters per minute. Detector data collection rates can reach 100 hertz, and injection cycle times can be as low as 15 seconds.[1]
The system uses a solvent delivery pump that incorporates SmartFlow technology to maintain flow accuracy regardless of mobile-phase composition, and SpinFlow mixing technology to balance gradient delay volume against mixing efficiency. The autosampler provides precise injections across a wide range of volumes and supports sample formats from 384-well plates to 10-milliliter vials.[1]
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| DGP-3600RS | — | — | Dual-gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| DGP-3600SD | — | — | Dual-gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| DGP-3600SDN | — | — | Dual-gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| HPG-3200RS | — | — | High-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| HPG-3200SD | — | — | High-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| HPG-3400RS | — | — | High-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| HPG-3400SD | — | — | High-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| ISO-3100BM | — | — | Isocratic pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| ISO-3100SD | — | — | Isocratic pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| LPG-3400RS | — | — | Quaternary low-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| LPG-3400SD | — | — | Quaternary low-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
| LPG-3400SDN | — | — | Quaternary low-pressure gradient pump, part of 2G pump series | knowledge1.thermofisher.com[2] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The UltiMate 3000 standard systems support pressures up to 620 bar (approximately 9,000 psi).[1]
The maximum flow rate is up to 10 milliliters per minute.[1]
Injection cycle times can be as low as 15 seconds.[1]
Available detectors include ultraviolet-visible absorbance (diode array, multiple wavelength, and variable wavelength), fluorescence, refractive index, charged aerosol, electrochemical, and single-quadrupole mass spectrometry.[1]
The thermostatted column compartment can hold up to twelve columns.[1]
The following facts about the UltiMate 3000 High Performance Liquid Chromatography are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the UltiMate 3000 High Performance Liquid Chromatography are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the UltiMate 3000 High Performance Liquid Chromatography are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the UltiMate 3000 High Performance Liquid Chromatography are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the UltiMate 3000 High Performance Liquid Chromatography is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the UltiMate 3000 High Performance Liquid Chromatography are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Oct 2, 2026.
The ABM-407B-2-S-CE-S293 is a robot.
The Applied Materials 0010-03485 Magnet Assy is a spare part used in 300mm PVD processes.