Waferpedia

Tektronix

DPO 5204 B Digital Phosphor Oscilloscope

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Tektronix logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz[1]

Performance

±1.5%, derated at 0.10%/°C above 30 °C[1]

Optics

8 bits (>11 bits with Hi Res)[1]

What is it?

The Tektronix DPO 5204 B is a 2 GHz, 4-channel digital phosphor oscilloscope with a 10/5 GS/s sample rate and 50 M/25 M record length.

What do the numbers mean?

Power & electrical4

Bandwidth Limits
1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz[1]
Accurate?
Input Sensitivity Range
1 MΩ: 1 mV/div to 10 V/div; 50 Ω: 1 mV/div to 1 V/div[1]
Accurate?
Maximum Input Voltage (1 MΩ)
300 VRMS CAT II, with peaks ≤ ±425 V[1]
Accurate?
Maximum Input Voltage (50 Ω)
5 VRMS, with peaks ≤ ±20 V[1]
Accurate?

Optics & imaging1

Vertical Resolution
8 bits (>11 bits with Hi Res)[1]
Accurate?

Performance1

DC Gain Accuracy
±1.5%, derated at 0.10%/°C above 30 °C[1]
Accurate?

Dimensions & facilities2

Dimensions (H x W x D)
233 mm x 439 mm x 206 mm[1]
Accurate?
Weight (Net)
6.7 kg (14.9 lb)[1]
Accurate?

Configuration & options16

Bandwidth
2 GHz[1]
Accurate?
Input Channels
4[1]
Accurate?
Maximum Sample Rate (1 or 2 channels)
10 GS/s[1]
Accurate?
Maximum Sample Rate (All channels)
5 GS/s[1]
Accurate?
Maximum Record Length (standard)
50 M (1 or 2 ch) / 25 M (4 ch)[1]
Accurate?
Maximum Record Length (with Option 10RL)
250 M (1 or 2 ch) / 125 M (4 ch)[1]
Accurate?
Rise Time (Calculated)
175 ps[1]
Accurate?
Effective Number of Bits (Typical)
6 bits[1]
Accurate?
Maximum Equivalent Time Sampling Rate
400 GS/s[1]
Accurate?
Maximum Waveform Capture Rate
>250,000 wfms/s with FastAcq® acquisition[1]
Accurate?
Input Coupling
AC, DC[1]
Accurate?
Input Resistance
1 MΩ ±1%, 50 Ω ±1%[1]
Accurate?
Position Range
±5 divisions[1]
Accurate?
Delay between any Two Channels (Typical)
≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)[1]
Accurate?
Power Consumption
275 W maximum[1]
Accurate?
Operating Temperature
0 °C to +50 °C[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
DPO5034B——350 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscopetestequipmenthq.com[1]
DPO5054B——500 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscopetestequipmenthq.com[1]
DPO5104B——1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscopetestequipmenthq.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Bandwidth Limits1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz[1]
  • Input Sensitivity Range1 MΩ: 1 mV/div to 10 V/div; 50 Ω: 1 mV/div to 1 V/div[1]
  • Maximum Input Voltage (1 MΩ)300 VRMS CAT II, with peaks ≤ ±425 V[1]
  • Maximum Input Voltage (50 Ω)5 VRMS, with peaks ≤ ±20 V[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the bandwidth of the Tektronix DPO5204B?

The DPO5204B is available in 2 GHz, 1 GHz, 500 MHz, and 350 MHz bandwidth models.[1]

What is the maximum real-time sample rate of the DPO5204B?

The DPO5204B offers up to 10 GS/s real-time sample rate on one or two channels and up to 5 GS/s on all four channels.[1]

What is the maximum record length of the DPO5204B?

The DPO5204B supports up to 250 megapoint record length with MultiView zoom.[1]

Does the DPO5204B support serial protocol decoding?

The DPO5204B can be equipped to decode common serial protocols, providing a comprehensive view of systems.[1]

Not publicly documented

The following facts about the DPO 5204 B Digital Phosphor Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the DPO 5204 B Digital Phosphor Oscilloscope are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the DPO 5204 B Digital Phosphor Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the DPO 5204 B Digital Phosphor Oscilloscope are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the DPO 5204 B Digital Phosphor Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the DPO 5204 B Digital Phosphor Oscilloscope are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]testequipmenthq.com — testequipmenthq.comtestequipmenthq.com
  2. [2]Equipment inventory listing
Was this page accurate?

Last updated Sep 23, 2026.

Compare with similar tools

View all →