Waferpedia

Perkin Elmer

Lambda 900

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Lambda 900 — Inventory photo
Fig. 01Lambda 900Inventory photo[1]

Performance

±0.003 A at 1 A[2]

Optics

175 nm to 3300 nm[3]

What is it?

The Perkin Elmer Lambda 900 is a double-beam, double-monochromator UV-Vis-NIR absorption spectrometer covering 175–3300 nm.

What do the numbers mean?

Optics & imaging5

Optical system
Double-beam, double monochromator ratio recording system[2]
Accurate?
Wavelength range
175 nm to 3300 nm[3]
Accurate?
Wavelength accuracy (UV-Vis)
±0.08 nm[2]
Accurate?
Wavelength accuracy (NIR)
±0.30 nm[2]
Accurate?
Slit width range
0.05–5 nm[3]
Accurate?

Performance1

Photometric accuracy
±0.003 A at 1 A[2]
Accurate?

Configuration & options5

Sources
Tungsten-halogen and deuterium lamps[2]
Accurate?
Photometric range
±6 A[2]
Accurate?
Grating (UV/Vis)
1440 lines/mm[3]
Accurate?
Grating (NIR)
360 lines/mm[3]
Accurate?
Integration time (UV/Vis)
0.04–10 s[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Lambda 900 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Lambda 900 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Lambda 900 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Lambda 900 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Lambda 900 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Lambda 900 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]spectralabsci.comspectralabsci.com
  3. [3]chem.uci.educhem.uci.edu
Was this page accurate?

Last updated Oct 3, 2026.

Compare with similar tools

View all →