Waferpedia

MKS

627H

MKS 627H family
Research Quality: 30% complete
MKS627H
No photo available yet

Vacuum

0.02 to 25,000 Torr[1]

Performance

0.12% or 0.15% of reading[1]

How it works

The 627H operates on the capacitance manometer principle, using a metal diaphragm that deflects in response to applied pressure. The diaphragm is heated and maintained at a constant 45°C temperature, which helps minimize the effects of ambient thermal variations on measurement accuracy. The sensor is fully welded and leak-checked, with the process gas contained within the sensor even in case of diaphragm failure.[1]

Applications

Typical application areas include plasma-based processes such as chemical vapor deposition and etching, where maintaining a specific process pressure is essential for film uniformity and etch rate control. The sensor may also be used in physical vapor deposition, as well as in any vacuum chamber where real-time pressure monitoring is required to ensure process repeatability.[1]

What do the numbers mean?

Vacuum & pumping2

Full Scale range
0.02 to 25,000 Torr[1]
Accurate?
Overpressure limit
45 psia (310 kPa) or 120% of full scale, whichever is greater[1]
Accurate?

Performance1

Accuracy
0.12% or 0.15% of reading[1]
Accurate?

Control & software1

Temperature control
45°C[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Full Scale range0.02 to 25,000 Torr[1]
  • Overpressure limit45 psia (310 kPa) or 120% of full scale, whichever is greater[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the full scale pressure range of the 627H?

The 627H has a full scale range of 0.02 to 25,000 Torr (2.67 to 3.33 x 10^6 Pa).[1]

What is the accuracy of the 627H?

The 627H provides an accuracy of 0.12% or 0.15% of reading, depending on the model configuration.[1]

What is the overpressure limit of the 627H?

The overpressure limit is 45 psia (310 kPa) or 120% of full scale, whichever is greater.[1]

What is the operating temperature control of the 627H?

The 627H operates with a temperature control of 45°C.[1]

Not publicly documented

The following facts about the 627H are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 627H are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 627H are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 627H are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 627H are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 627H is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]api.p1.mks.com — api.p1.mks.comapi.p1.mks.com
Was this page accurate?

Last updated Sep 22, 2026.

Compare with similar tools

View all →