Attribute
OEMABMTenney
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotTenney Environmental
Specifications
ModelABM-407B-2-S-CE-S293[1]—
DescriptionROBOT[1]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[1]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[1]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[1]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[1]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[1]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[1]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[1]—
Temperature Range—-62 to +82°C (Tenney #1)[2]
Temperature Stability—±1°C at steady state (Tenney #1)[2]
Temperature Accuracy—±0.5°C internal sensor (Tenney #1)[2]
Humidity Range—20% to 95% relative humidity (Tenney #1)[2]
Humidity Stability—±5% at steady state (Tenney #1)[2]
Humidity Accuracy—±0.5% internal sensor (Tenney #1)[2]
Interior Volume—234 cubic feet (72" wide × 72" deep × 78" tall) (Tenney #1)[2]
Control System—VersaTenn V microprocessor with PID control (Tenney #1)[2]
Cooling System—Two-stage refrigeration system (Tenney #1)[2]
Heating System—Electric resistance heaters (Tenney #1)[2]
Product type—Environmental test chambers and walk-in rooms[3]
Testing capabilities—Temperature, humidity, altitude, vibration, and vacuum testing[3]
Walk-in chamber use—Large walk-in enclosure used to test equipment under simulated environmental conditions[2]
Temperature range—-62 to +82°C[2]
Temperature stability—±1°C (at steady state)[2]
Temperature accuracy—±0.5°C (internal sensor)[2]
Humidity range—20% to 95% relative humidity[2]
Humidity stability—±5% (at steady state conditions)[2]
Humidity accuracy—±0.5% (internal sensor)[2]
Interior volume—234 cubic feet (72" wide × 72" deep × 78" tall)[2]
Control system—VersaTenn V microprocessor control system with PID temperature and humidity control[2]
Automation—Completely automatic[2]
Logging—Internal log function keeps a continuous record of chamber temperature and humidity[2]
Programmable profiles—Allows preprogrammed temperature/humidity profiles[2]
Additional test capabilities—Liquid, freezing, and precipitation tests[2]
Altitude chamber size range—5 to 64 cubic feet[3]
Altitude chamber temperature range—-68°C to +177°C[3]
Altitude chamber humidity capability—20% to 95% RH in the dry bulb range of +20°C to +85°C, limited by a 5°C dewpoint[3]
Altitude conditions—Site level to 100,000 feet[3]
Combined temperature and altitude—60,000 feet maximum[3]
Altitude chamber control—±0.3°C and ±2% RH[3]
Sources (3)Every fact above is drawn from these public sources
  1. [1]dealer listingsemistarcorp.com
  2. [2]weather.govweather.gov
  3. [3]tenney.comtenney.com