Comparison ledger
KLA 1007, Tektronix 370 A Programmable Curve Tracer, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 1007KLA | 370 A Programmable Curve TracerTektronix |
|---|---|---|
| OEM | KLA | Tektronix |
| Category | Test & Probe | Test & Probe |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | KLA 1007 | Tektronix 370 A Programmable Curve Tracer |
| Specifications | ||
| Manufacturer | KLA[1] | — |
| Model | 1007[1] | — |
| Description | Wafer Prober[1] | — |
| Wafer size | 150 mm[1] | — |
| Convertible to 8 inch wafer size | Yes[1] | — |
| Vintage | 01.06.1995[1] | — |
| Make | KLA[2] | — |
| Equipment type | Prober[2] | — |
| Configuration | — | Built onto a cart[3] |
| Collector Supply Modes | — | AC, ±DC, ±Leakage, ±Rectified Sine[4] |
| Maximum Peak Current (16 V range) | — | 10 A (20 A pulsed)[4] |
| Maximum Peak Current (80 V range) | — | 2 A (4 A pulsed)[4] |
| Maximum Peak Current (400 V range) | — | 0.4 A (0.8 A pulsed)[4] |
| Maximum Peak Current (2000 V range) | — | 0.05 A (0.1 A pulsed)[4] |
| Step Generator Modes | — | Stair step: DC, 80 µs pulse, 300 µs pulse[4] |
| Step Range (Current) | — | 50 nA to 200 mA in 1-2-5 sequence[4] |
| Step Range (Voltage) | — | 50 mV to 2 V in 1-2-5 sequence[4] |
| Offset | — | Up to ±10X step amplitude[4] |
| Number of Steps | — | 0 to 10[4] |
| Collector Current Measurement Range | — | 100 nA/div (1 nA resolution) to 2 A/div[4] |
| Collector Current Accuracy | — | 1.5% of cursor readout +0.05 div of setting (with dot cursor)[4] |
| Emitter Current Measurement Range | — | 1 nA/div (10 pA resolution) to 2 mA/div[4] |
| Emitter Current Accuracy | — | 1.5% of cursor readout +0.05 div of setting +1 nA[4] |
| Measurement Resolution | — | 1 nA current resolution, 2 mV voltage resolution[4] |
| Safety Certifications | — | UL1244, CSA231, HD401 S1 K475[4] |
| Interface | — | IEEE Standard 488.1-1987, RS-232-C, Tektronix Standard Codes and Formats[4] |
| Storage | — | 3.5-inch MS DOS-compatible disk, nonvolatile memory[4] |
| Test Fixture Adapters | — | A1001-A1005 (Kelvin sensing), 3-Pin adapters (non-Kelvin), A1023/A1024 surface mount adapters[4] |
| Accessories | — | K475 Instrument Cart[4] |
| Display Features | — | Waveform Comparison, Envelope Display, Waveform Averaging, Dot Cursor[4] |
| EMC Compliance | — | Directive 89/336/EEC, EN 55011 Class B (radiated and conducted), EN 60555-2[5] |
| Installation Category | — | CAT II (as defined in IEC 1010-1, Annex J)[5] |
Plan your fab